Oil instrument
Recommend Oil instrument
Hot Oil instrument
Automatic Determination of Gas Content of KHQ8500 Insulation Oil
Source:Shandong Ketong Author:Shandong Ketong Date:2020-03-17 Visits:688
型号:
品牌:
产地:
价格:
Khq8500 type insulating oil gas content automatic tester
(developed according to the latest national standards)
Applicable standard: DL / T 423-2009
Instrument characteristics
◆ patented sample quantitative calibration system: introduce a certain amount of oil sample (about 50ml) into the degassing system for degassing.
Special degassing system: vacuum pressure spray, automatic constant temperature control, high degassing efficiency.
◆ high precision data detection and processing system: the high precision and high stability differential pressure sensor at the inlet is used to collect the differential pressure signal generated between the internal pressure of degassing tank after degassing and the pressure before entering the oil, which is amplified and processed by the data processing system, and then the calculated volume percentage of air content in the oil is directly displayed on the display screen. Make the test data more accurate and repeatable.
◆ international leading waste oil collection system: collect the cleaning liquid and test oil samples entering the instrument and discharge them automatically after each test.
◆ the sensor for atmospheric pressure measurement and ambient temperature can automatically measure your ambient temperature and atmospheric pressure whenever and wherever you are, automatically convert to the air content at 0 ℃ under standard atmospheric pressure, and display directly on the LCD screen, making your work easier.
◆ the unique gas injection reverse standard test procedure can let you easily test whether the instrument calibration or measurement is correct.
◆ the instrument can automatically store the test results, and at the same time store the time, temperature, atmospheric pressure, etc. during the test, so that you can easily access the data.
◆ friendly interface display system: TFT real color LCD screen imitates windows interface display, Chinese menu touch operation, intuitive and friendly, simple and convenient.
Technical performance
◆ detection sensitivity: the minimum detection amount is less than 0.2%
◆ repeatability: results of several parallel tests of the same oil sample, repeatability < 10%
◆ anti interference: voltage noise: 1000vp-p
◆ protection structure: suitable for IP65f
◆ working power supply: AC 220V ± 10% 50Hz
◆ environmental humidity: 0-85% (no condensation)
Measurement parameters:
◆ calibration volume: 1.00 ~ 2.00ml
◆ test oil volume: 22.5 + 1.0ml
◆ temperature setting: room temperature ~ 70.0 ℃
◆ time setting: 0-15 min
◆ PID temperature control parameter: P: 30 I: 5 d: 500
◆ temperature control accuracy: + 2.0 ℃
◆ result accuracy: better than DL / t-703 reproducibility index requirements
Electrical specifications:
◆ input voltage: ac200-240v 1.5A
◆ power consumption: less than 500W
◆ withstand voltage: ac1000v-10ma for 1 minute
◆ insulation impedance: DC500v - about 10m Ω (between signal and ground)
Environmental conditions:
◆ vibration resistance: 10-25hz (2G in X, y and Z directions for 30 minutes respectively)
◆ anti interference: voltage noise: 1000vp-p
◆ surrounding air: no corrosive gas
◆ protection structure: suitable for IP65f
Structural parameters:
(developed according to the latest national standards)
Applicable standard: DL / T 423-2009
Instrument characteristics
◆ patented sample quantitative calibration system: introduce a certain amount of oil sample (about 50ml) into the degassing system for degassing.
Special degassing system: vacuum pressure spray, automatic constant temperature control, high degassing efficiency.
◆ high precision data detection and processing system: the high precision and high stability differential pressure sensor at the inlet is used to collect the differential pressure signal generated between the internal pressure of degassing tank after degassing and the pressure before entering the oil, which is amplified and processed by the data processing system, and then the calculated volume percentage of air content in the oil is directly displayed on the display screen. Make the test data more accurate and repeatable.
◆ international leading waste oil collection system: collect the cleaning liquid and test oil samples entering the instrument and discharge them automatically after each test.
◆ the sensor for atmospheric pressure measurement and ambient temperature can automatically measure your ambient temperature and atmospheric pressure whenever and wherever you are, automatically convert to the air content at 0 ℃ under standard atmospheric pressure, and display directly on the LCD screen, making your work easier.
◆ the unique gas injection reverse standard test procedure can let you easily test whether the instrument calibration or measurement is correct.
◆ the instrument can automatically store the test results, and at the same time store the time, temperature, atmospheric pressure, etc. during the test, so that you can easily access the data.
◆ friendly interface display system: TFT real color LCD screen imitates windows interface display, Chinese menu touch operation, intuitive and friendly, simple and convenient.
Technical performance
◆ detection sensitivity: the minimum detection amount is less than 0.2%
◆ repeatability: results of several parallel tests of the same oil sample, repeatability < 10%
◆ anti interference: voltage noise: 1000vp-p
◆ protection structure: suitable for IP65f
◆ working power supply: AC 220V ± 10% 50Hz
◆ environmental humidity: 0-85% (no condensation)
Measurement parameters:
◆ calibration volume: 1.00 ~ 2.00ml
◆ test oil volume: 22.5 + 1.0ml
◆ temperature setting: room temperature ~ 70.0 ℃
◆ time setting: 0-15 min
◆ PID temperature control parameter: P: 30 I: 5 d: 500
◆ temperature control accuracy: + 2.0 ℃
◆ result accuracy: better than DL / t-703 reproducibility index requirements
Electrical specifications:
◆ input voltage: ac200-240v 1.5A
◆ power consumption: less than 500W
◆ withstand voltage: ac1000v-10ma for 1 minute
◆ insulation impedance: DC500v - about 10m Ω (between signal and ground)
Environmental conditions:
◆ vibration resistance: 10-25hz (2G in X, y and Z directions for 30 minutes respectively)
◆ anti interference: voltage noise: 1000vp-p
◆ surrounding air: no corrosive gas
◆ protection structure: suitable for IP65f
Structural parameters:
On a Oil instrument:KGC2010D gas chromatograph analysis system
The next Oil instrument:KJS5600 type precision insulation oil dielectric loss and resistivity automatic measuring instr...