Kpx216 fluorine ion concentration meter
Technical requirements
1. Overall instrument design:
1) Units can be selected for calibration and measurement, and switching;
2) Set the standard solution of fluorine ion concentration at two points, calibrate automatically, and directly measure the fluorine ion concentration of the sample;
3) The intelligent mixer can set a fixed mixing speed, convenient and reliable;
4) It has intelligent functions such as automatic calibration, automatic temperature compensation, data storage, timing measurement, clock display, function setting and self diagnosis information;
5) Data stability prompt sign;
6) The instrument complies with IP54 dust and splash proof grade.
2. Technical indicators:
1) Fluoride measurement:
Measurement range: electrometer: (0.00-6.00) pf;
Display unit: PF, mol / L, mg / L, PPM accuracy: ± 0.01 pf temperature compensation range: (0 - 50) ℃
2) MV measurement: measurement range: ± 1999.9 MV resolution: 0.1mv accuracy: ± 0.1% FS
3) Temperature measurement: measurement range: (- 10-110) ℃ resolution: 0.1 ℃ accuracy: (5-60) ℃ range: ± 0.5 ℃ rest range: ± 1.0 ℃
4) Other parameters: data storage: 600 sets of power supply: 220V size and weight: 160 x 190 x 70mm / 880g
Technical requirements
1. Overall instrument design:
1) Units can be selected for calibration and measurement, and switching;
2) Set the standard solution of fluorine ion concentration at two points, calibrate automatically, and directly measure the fluorine ion concentration of the sample;
3) The intelligent mixer can set a fixed mixing speed, convenient and reliable;
4) It has intelligent functions such as automatic calibration, automatic temperature compensation, data storage, timing measurement, clock display, function setting and self diagnosis information;
5) Data stability prompt sign;
6) The instrument complies with IP54 dust and splash proof grade.
2. Technical indicators:
1) Fluoride measurement:
Measurement range: electrometer: (0.00-6.00) pf;
Display unit: PF, mol / L, mg / L, PPM accuracy: ± 0.01 pf temperature compensation range: (0 - 50) ℃
2) MV measurement: measurement range: ± 1999.9 MV resolution: 0.1mv accuracy: ± 0.1% FS
3) Temperature measurement: measurement range: (- 10-110) ℃ resolution: 0.1 ℃ accuracy: (5-60) ℃ range: ± 0.5 ℃ rest range: ± 1.0 ℃
4) Other parameters: data storage: 600 sets of power supply: 220V size and weight: 160 x 190 x 70mm / 880g