Oil instrument
Recommend Oil instrument
Hot Oil instrument
KZD5608 Multi-function Automatic Oscillator
Source:Shandong Ketong Author:Shandong Ketong Date:2020-03-17 Visits:862
型号:
品牌:
产地:
价格:
Kzd5608 multi-function full-automatic oscillator
Applicable standard: GB / t17625-1998 GB / t7598-2008 dl429.4-91
Instrument characteristics
◆ large screen LCD, Chinese menu, fool button operation
Adopt microcomputer control, PID self-tuning temperature control mode, accurate temperature control
◆ high precision and high graduation value PT1000 temperature sensor is adopted, so the detection accuracy is higher and more accurate
◆ high performance switching power supply has automatic power-off protection function for over-voltage, over-current and over temperature, which is safe and reliable
◆ adopt imported linear motor, ensure linear oscillation, with fatigue resistance, vibration resistance, maintenance free, low noise performance and stability
◆ adopt high-power centrifugal fan, with large air volume, uniform air supply, space temperature field average speed of temperature rise, greatly improving the degassing rate
◆ it is equipped with an external thermometer jack, which is convenient for the operator to observe and compare.
◆ small size, light weight and elegant appearance.
◆ it can put 8 100ml syringes or 8 50ml syringes at the same time (optional), (Chromatographic degassing oscillation)
◆ four 250ml triangular bottles can be put at the same time (water soluble acid oscillation)
Technical performance
◆ measurement range: room temperature ~ 120 ℃;
◆ temperature control accuracy: room temperature ~ 50 ℃ ± 0.2 ℃;
50℃~100℃±0.3℃
100~120℃±0.5℃
◆ oscillation frequency: 275 ± 3 times / min;
◆ oscillation amplitude: 35mm;
◆ chromatographic shaking degassing: shaking for 20 minutes, standing for 10 minutes; constant temperature 50 ℃
◆ water soluble acid oscillation: oscillation for 5 minutes, constant temperature 75 ℃;
◆ custom oscillation: set the oscillation and static time at will within 0-99 minutes ± 5 seconds
Set the temperature arbitrarily within the range of room temperature to 100;
◆ noise: < 40 dB
◆ boundary dimension: (length × width × height): 500 × 360 × 360 (mm)
◆ power: 35W
◆ power supply: AC 220V ± 10%
◆ frequency: 50Hz ± 5%
◆ applicable ambient temperature: 5 ℃ ~ 45 ℃
◆ applicable environmental humidity: ≤ 85%
Applicable standard: GB / t17625-1998 GB / t7598-2008 dl429.4-91
Instrument characteristics
◆ large screen LCD, Chinese menu, fool button operation
Adopt microcomputer control, PID self-tuning temperature control mode, accurate temperature control
◆ high precision and high graduation value PT1000 temperature sensor is adopted, so the detection accuracy is higher and more accurate
◆ high performance switching power supply has automatic power-off protection function for over-voltage, over-current and over temperature, which is safe and reliable
◆ adopt imported linear motor, ensure linear oscillation, with fatigue resistance, vibration resistance, maintenance free, low noise performance and stability
◆ adopt high-power centrifugal fan, with large air volume, uniform air supply, space temperature field average speed of temperature rise, greatly improving the degassing rate
◆ it is equipped with an external thermometer jack, which is convenient for the operator to observe and compare.
◆ small size, light weight and elegant appearance.
◆ it can put 8 100ml syringes or 8 50ml syringes at the same time (optional), (Chromatographic degassing oscillation)
◆ four 250ml triangular bottles can be put at the same time (water soluble acid oscillation)
Technical performance
◆ measurement range: room temperature ~ 120 ℃;
◆ temperature control accuracy: room temperature ~ 50 ℃ ± 0.2 ℃;
50℃~100℃±0.3℃
100~120℃±0.5℃
◆ oscillation frequency: 275 ± 3 times / min;
◆ oscillation amplitude: 35mm;
◆ chromatographic shaking degassing: shaking for 20 minutes, standing for 10 minutes; constant temperature 50 ℃
◆ water soluble acid oscillation: oscillation for 5 minutes, constant temperature 75 ℃;
◆ custom oscillation: set the oscillation and static time at will within 0-99 minutes ± 5 seconds
Set the temperature arbitrarily within the range of room temperature to 100;
◆ noise: < 40 dB
◆ boundary dimension: (length × width × height): 500 × 360 × 360 (mm)
◆ power: 35W
◆ power supply: AC 220V ± 10%
◆ frequency: 50Hz ± 5%
◆ applicable ambient temperature: 5 ℃ ~ 45 ℃
◆ applicable environmental humidity: ≤ 85%
On a Oil instrument:Automatic Viscosity Measuring Instrument for KYN3102 Petroleum Products